پی ال سی زیمنس "6ES7-315-2AG10-0AB0"
SIMATIC S7-300 CPU 315-2 DP The CPU with medium to large program memory and quantity framework for the use, if required, of SIMATIC Engineering Tools,High processing performance in binary and floating-point arithmetic ,PROPROFIBUS DP master/slave interface ,For extensive I/O .
مشخصات
- شرکت سازنده :
- siemens
- کشور سازنده :
- آلمان
- CPU315 2DP :
- 6ES7-315-2AG10-0AB0
- وضعیت :
- نو
- قیمت :
- ریال45.500.000
توضیحات محصول
CPU S7-315 "SERIES"
Part no | TYPE | specification |
6ES7 315-1AF00-0AB0 | CPU315 | Work memory 48 KB; 0.3 ms/1000 instructions; MPI connection; for multi-tier configuration up to 32 modules |
6ES7 315-1AF01-0AB0 | CPU315 | Work memory 128 KB; 0.3 ms/1000 instructions; MPI connection; multi-tier configuration up to 32 modules |
6ES7 315-1AF02-0AB0 | CPU315 | Work memory 48 KB; 0.3 ms/1000 instructions; MPI connection; multi-tier configuration up to 32 modules |
6ES7 315-1AF03-0AB0 | CPU315 | Work memory 48 KB; 0.3 ms/1000 instructions; MPI connection; multi-tier configuration up to 32 modules; S7 Communication (loadable FBs/FCs); firmware V1.2 |
6ES7 315-2AF00-0AB0 | 315-2 DP | Work memory 48 KB; 0.3 ms/1000 instructions; MPI + DP connections; for multi-tier configuration up to 32 modules |
6ES7 315-2AF01-0AB0 | 315-2 DP | Work memory 48 KB; 0.3 ms/1000 instructions; MPI + DP connections; for multi-tier configuration up to 32 modules |
6ES7 315-2AF02-0AB0 | 315-2 DP | Work memory 64 KB; 0.3 ms/1000 instructions; MPI + DP connections; for multi-tier configuration up to 32 modules |
6ES7 315-2AF03-0AB0 | 315-2 DP | Work memory 64 KB; 0.3 ms/1000 instructions; MPI+ DP connection (DP master or DP slave); multi-tier configuration up to 32 modules, send and receive capability for direct data exchange, constant bus cycle time, routing, S7 Communication (loadable FBs/FCs), firmware V1.2 |
6ES7 315-2AF82-0AB0 | 315-2 DP | Work memory 64 KB; 0.3 ms/1000 instructions; MPI + DP connection (DP master or DP slave); multi-tier configuration up to 32 modules; extended environmental conditions |
6ES7 315-2AF83-0AB0 | 315-2 DP | Work memory 64 KB; 0.3 ms/1000 instructions; MPI+ DP connection (DP master or DP slave); multi-tier configuration up to 32 modules, expanded environmental conditions, send and receive capability for direct data exchange, constant bus cycle time, routing, S7 Communication (loadable FBs/FCs), firmware V1.2 |
6ES7 315-2AG10-0AB0 | 315-2 DP | Work memory 128KB; 0.1ms/1000 instructions; MPI+ DP connection (DP master or DP slave); multi-tier configuration up to 32 modules; Send and receive capability for direct data exchange, constant bus cycle time, routing, S7 Communikation (loadable FBs/FCs), firmware V2.6 |
6ES7 315-2AH14-0AB0 | 315-2 DP | Work memory 256KB; 0.05ms/1000 instructions; MPI+ DP connection (DP master or DP slave); multi-tier configuration up to 32 modules; Send and receive capability for direct data exchange, constant bus cycle time, routing, S7 Communikation (loadable FBs/FCs), firmware V3.3 |
6ES7 315-2EG10-0AB0 | 315-2 PN/DP | 128 KB work memory; 0.1 ms/1000 instructions; PROFINET connection; S7 Communication (loadable FBs/FCs); PROFINET IO-Controller; PROFINET CBA; PROFINET CBA-Proxy; transport protocol; combined MPI/DP connection (MPI or DP master or DP slave); multi-tier configuration up to 32 modules; constant DP bus cycle time; routing; firmware V2.3;also available as SIPLUS module with order number 6AG1 317-6FF00-2AB0 |
6ES7 315-2EH13-0AB0 | 315-2 PN/DP | 256 KB work memory; 0.1 ms/1000 instructions; PROFINET connection; S7 Communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT; PROFINET interface and 1 port; PROFINET CBA; PROFINET CBA-Proxy; TCP/IP transport protocol; combined MPI/DP connection (MPI or DP master or DP slave); multi-tier configuration up to 32 modules; constant DP bus cycle time; routing; firmware V2.6 |
6ES7 315-2EH14-0AB0 | 315-2 PN/DP | 384 KB work memory; 0.05ms/1000 instructions; PROFINET connection; S7 Communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 2 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; TCP/IP transport protocol; combined MPI/DP connection (MPI or DP master or DP slave); multi-tier configuration up to 32 modules; constant DP bus cycle time; routing; firmware V3.2 |
6ES7 315-6FF01-0AB0 | 315F-2 DP | Work memory 192KB; 0.3ms/1000 instructions; MPI+ DP connection (DP master or DP slave); multi-tier configuration up to 32 modules, send and receive capability for direct data exchange, constant bus cycle time, routing, S7 Communication (loadable FBs/FCs), firmware V2.6, can be used for security applications; supports PROFIsafe V2 |
6ES7 315-6FF04-0AB0 | 315F-2 DP | Work memory 384KB; 0.05ms/1000 instructions; MPI+ DP connection (DP master or DP slave); multi-tier configuration up to 32 modules, send and receive capability for direct data exchange, constant bus cycle time, routing, S7 Communication (loadable FBs/FCs), firmware V3.3, can be used for security applications; supports PROFIsafe V2 |
6ES7 315-2FH10-0AB0 | 315F-2 PN/DP | Work memory 192KB; 0.1ms/1000 instructions; PROFINET connection; S7 Communication (loadable FBs/FCs); PROFINET IO-Controller; PROFINET CBA; PROFINET CBA-Proxy; Transport protocol TCP/IP; combined MPI/DP connection (MPI or DP master or DP slave); multi-tier installation up to 32 modules; equidistant DP bus cycle; Routing; firmware V2.3, can be used for safety applications |
6ES7 315-2FH13-0AB0 | 315F-2 PN/DP | 256 KB work memory; 0.1 ms/1000 instructions; PROFINET connection; S7 Communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT; PROFINET interface and 1 port; PROFINET CBA; PROFINET CBA-Proxy; TCP/IP transport protocol; combined MPI/DP connection (MPI or DP master or DP slave); multi-tier configuration up to 32 modules; constant DP bus cycle time; routing; firmware V2.6, can be used for safety applications; supports PROFIsafe V2 |
6ES7 315-2FJ14-0AB0 | 315F-2 PN/DP | 512 KB work memory; 0.05ms/1000 instructions; PROFINET connection; S7 Communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 2 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; TCP/IP transport protocol; combined MPI/DP connection (MPI or DP master or DP slave); multi-tier configuration up to 32 modules; constant DP bus cycle time; routing; firmware V3.2, can be used for safety applications; supports PROFIsafe V2 |