| Measurement line type | Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, threephase 4-wire, Voltage 4 channels, Current 4 channels, Isolated between each channel | | Measurement items | Voltage, Current, Voltage/current waveform peak, Active power, Reactive power, Apparent power, Power factor, Phase angle, Frequency, Current integration, Power integration, Efficiency, Loss, Voltage/current ripple factor | Noise measurement (FFT processing): RMS spectrum of voltage/current Harmonic measurement: RMS value, Content factor, Phase angle, Total distortion, Disequilibrium factor | | Additional functions (With optional 9791 or 9793 installed in the main unit) : Torque, Rotation, Frequency, Slip, or Motor output | | Harmonic measurement | Input: 4 ch, Synchronization frequency range: 0.5 Hz to 5 kHz, Number of harmonic orders: Max. 100th order | | Noise measurement | Number of channels: 1 ch (select one channel from CH1 to CH4), Maximum analysis frequency: 100 k/ 50 k/ 20 k/ 10 k/ 5 k/ 2 kHz | | Measurement range | Voltage range: 15 to 1500 V, 7 ranges | | Current range: 400 mA to 500 A (depends on current sensor, 20A/ 50A/ 200A/ or 500A rated) | | Power range: 6.0000 W to 2.2500 MW (depends on combination of voltage and current range) | | Frequency range: 0.5 Hz to 5 kHz | | Basic accuracy (45Hz to 66Hz) | Voltage: ±0.05 % rdg. ±0.05 % f.s. Current: ±0.05 % rdg. ±0.05 % f.s. (Defined at combined accuracy with dedicated sensors) Active power: ±0.05 % rdg. ±0.05 % f.s. (Defined at combined accuracy with dedicated sensors) Note: Accuracy for the high accuracy Models 3390-10 and Current Sensors are not defined individually. Please use these products in combination to obtain ±0.1% accuracy. | | Synchronization frequency range | 0.5 Hz to 5 kHz | | Frequency band | DC, 0.5 Hz to 150 kHz | | Data update rate | 50 ms (For harmonic measurement, depends on the synchronization frequency when less than 45 Hz) | | Display refresh rate | 200 ms (Independent of internal data update rate; waveform and FFT depend on the screen) | | Data save interval | OFF, 50 msec to 500 msec, 1 sec to 30 sec, 1 minute to 60 minutes, 15 settings | | External interfaces | LAN, USB (communication/ memory), RS-232C, CF card, Synchronization control | | Power supply | 100 to 240 V AC, 50/60 Hz, 140 VA max. | | Dimensions, mass | 340 mm (13.39 in) W × 170 mm (6.69 in) H × 157 mm (6.18 in) D, 4.8 kg (169.3 oz) | | Supplied accessories | Instruction Manual for Model 3390 ×1, Instruction Manual for Model 3390-10 ×1, Measurement Guide ×1, Power cord ×1, USB cable ×1, D-sub connector ×1 (when 9792 or 9793 is installed), Color label ×2 |
|