Product characteristics |
---|
Output signal | analog signal |
Measuring range | 0...10 bar | 0...145 psi | 0...1000 kPa | 0...1 MPa |
|
Process connection | threaded connection G 1/4 external thread Internal thread:M5 |
Application |
---|
System | gold-plated contacts |
Application | for industrial applications |
Media | liquids and gases |
Medium temperature [°C] | -25...90; (on request: -40...90 °C) |
Min. bursting pressure | |
Pressure rating | |
Type of pressure | relative pressure |
Electrical data |
---|
Operating voltage [V] | 9.6...32 DC |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Inputs / outputs |
---|
Number of inputs and outputs | Number of analog outputs: 1 |
Outputs |
---|
Total number of outputs | 1 |
Output signal | analog signal |
Number of analog outputs | 1 |
Analog current output [mA] | 4...20 |
Max. load [Ω] | 720; (Ub = 24 V; (Ub - 9,6 V) / 20 mA) |
Overload protection | yes |
Measuring/setting range |
---|
Measuring range | 0...10 bar | 0...145 psi | 0...1000 kPa | 0...1 MPa |
|
Accuracy / deviations |
---|
Repeatability [% of the span] | < 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Long-term stability [% of the span] | < ± 0,05; (per 6 months) |
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,1; (0...80 °C) |
Temperature coefficient span [% of the span / 10 K] | < ± 0,2; (0...80 °C) |
Reaction times |
---|
Step response time analogue output [ms] | 3 |
Operating conditions |
---|
Ambient temperature [°C] | -25...80 |
Storage temperature [°C] | -40...100 |
Protection | IP 65 |
Tests / approvals |
---|
EMC | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | EN 61000-4-3 HF radiated | 30 V/m | EN 61000-4-4 Burst | 2 kV | EN 61000-4-6 HF conducted | 10 V | radiation of interference | according to the automotive directive 2004/104/EC | CISPR 25 | | noise immunity | according to the automotive directive 2004/104/EC | ISO 11452-2 HF radiated | 100 V/m | ISO 7637-2 pulse | severity level 4 |
|
Shock resistance | DIN EN 60068-2-27 | 50 g (11 ms) | DIN EN 61373 | Category 3 |
|
Vibration resistance | DIN EN 60068-2-6 | 20 g (10...2000 Hz) | DIN EN 61373 | Category 2 |
|
MTTF [years] | 506 |
Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Railway applications | DIN EN 50155 / IEC 60571 | Klasse T3, C1, S1 |
|
Mechanical data |
---|
Weight [g] | 217 |
Material | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X |
Materials (wetted parts) | stainless steel (1.4305 / 303); ceramics; sealing: FKM DIN 3869-14 |
Min. pressure cycles | 100 million |
Process connection | threaded connection G 1/4 external thread Internal thread:M5 |
Restrictor element integrated | no (can be retrofitted) |
Remarks |
---|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12; Contacts: gold-plated |