Product characteristics |
---|
Output signal | switching signal |
Measuring range | 0...250 bar | 0...3630 psi | 0...25 MPa |
|
Process connection | threaded connection G 1/4 external thread Internal thread:M5 |
Application |
---|
System | gold-plated contacts |
Application | for industrial applications |
Media | liquids and gases |
Conditionally suitable for | For gaseous media the application is limited to max. 25 bar. |
Medium temperature [°C] | -25...80 |
Min. bursting pressure | |
Pressure rating | |
Type of pressure | relative pressure |
Electrical data |
---|
Operating voltage [V] | 9.6...30 DC; (PP2000 with sensor: > 18) |
Current consumption [mA] | < 45 |
Min. insulation resistance [MΩ] | 100; (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 0.3 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | switching signal |
Electrical design | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] | 2 |
Permanent current rating of switching output DC [mA] | 250 |
Switching frequency DC [Hz] | < 170 |
Short-circuit protection | yes |
Type of short-circuit protection | yes (non-latching) |
Overload protection | yes |
Measuring/setting range |
---|
Measuring range | 0...250 bar | 0...3630 psi | 0...25 MPa |
|
Set point SP | 3...250 bar | 40...3630 psi | 0.3...25 MPa |
|
Reset point rP | 2...249 bar | 20...3610 psi | 0.2...24.9 MPa |
|
In steps of | |
Accuracy / deviations |
---|
Switch point accuracy [% of the span] | < ± 1,5 |
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
Linearity deviation [% of the span] | < ± 0,5 |
Hysteresis deviation [% of the span] | < ± 0,1 |
Long-term stability [% of the span] | < ± 0,1; (per year) |
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (-25...80 °C) |
Temperature coefficient span [% of the span / 10 K] | < ± 0,3; (-25...80 °C) |
Reaction times |
---|
Response time [ms] | < 3 |
Damping for the switching output dAP [s] | 0...4 |
Software / programming |
---|
Adjustment of the switch point | programming unit / teach function |
Interfaces |
---|
Communication interface | EPS |
Operating conditions |
---|
Ambient temperature [°C] | -25...80 |
Storage temperature [°C] | -40...100 |
Protection | IP 67 |
Tests / approvals |
---|
EMC | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | EN 61000-4-3 HF radiated | 10 V/m | EN 61000-4-4 Burst | 2 kV | EN 61000-4-6 HF conducted | 10 V |
|
Shock resistance | DIN IEC 68-2-27 | 50 g (11 ms) |
|
Vibration resistance | DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
|
Mechanical data |
---|
Material | stainless steel (1.4301 / 304); PA |
Materials (wetted parts) | stainless steel (1.4305 / 303); ceramics; FKM |
Min. pressure cycles | 100 million |
Process connection | threaded connection G 1/4 external thread Internal thread:M5 |
Restrictor element integrated | no (can be retrofitted) |
Displays / operating elements |
---|
Display | Power | LED, green | Switching status | 2 x LED, yellow |
|
Teach function | yes |
Remarks |
---|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12; Contacts: gold-plated |