| Product characteristics |
|---|
| Output signal | switching signal |
| Measuring range | | 0...250 bar | 0...3630 psi | 0...25 MPa |
|
| Process connection | threaded connection G 1/4 external thread Internal thread:M5 |
| Application |
|---|
| System | gold-plated contacts |
| Application | for industrial applications |
| Media | liquids and gases |
| Conditionally suitable for | For gaseous media the application is limited to max. 25 bar. |
| Medium temperature [°C] | -25...80 |
| Min. bursting pressure | |
| Pressure rating | |
| Type of pressure | relative pressure |
| Electrical data |
|---|
| Operating voltage [V] | 9.6...30 DC; (PP2000 with sensor: > 18) |
| Current consumption [mA] | < 45 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | 0.3 |
| Inputs / outputs |
|---|
| Number of inputs and outputs | Number of digital outputs: 2 |
| Outputs |
|---|
| Total number of outputs | 2 |
| Output signal | switching signal |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Max. voltage drop switching output DC [V] | 2 |
| Permanent current rating of switching output DC [mA] | 250 |
| Switching frequency DC [Hz] | < 170 |
| Short-circuit protection | yes |
| Type of short-circuit protection | yes (non-latching) |
| Overload protection | yes |
| Measuring/setting range |
|---|
| Measuring range | | 0...250 bar | 0...3630 psi | 0...25 MPa |
|
| Set point SP | | 3...250 bar | 40...3630 psi | 0.3...25 MPa |
|
| Reset point rP | | 2...249 bar | 20...3610 psi | 0.2...24.9 MPa |
|
| In steps of | |
| Accuracy / deviations |
|---|
| Switch point accuracy [% of the span] | < ± 1,5 |
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) |
| Linearity deviation [% of the span] | < ± 0,5 |
| Hysteresis deviation [% of the span] | < ± 0,1 |
| Long-term stability [% of the span] | < ± 0,1; (per year) |
| Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (-25...80 °C) |
| Temperature coefficient span [% of the span / 10 K] | < ± 0,3; (-25...80 °C) |
| Reaction times |
|---|
| Response time [ms] | < 3 |
| Damping for the switching output dAP [s] | 0...4 |
| Software / programming |
|---|
| Adjustment of the switch point | programming unit / teach function |
| Interfaces |
|---|
| Communication interface | EPS |
| Operating conditions |
|---|
| Ambient temperature [°C] | -25...80 |
| Storage temperature [°C] | -40...100 |
| Protection | IP 67 |
| Tests / approvals |
|---|
| EMC | | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | | EN 61000-4-3 HF radiated | 10 V/m | | EN 61000-4-4 Burst | 2 kV | | EN 61000-4-6 HF conducted | 10 V |
|
| Shock resistance | | DIN IEC 68-2-27 | 50 g (11 ms) |
|
| Vibration resistance | | DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
|
| Mechanical data |
|---|
| Material | stainless steel (1.4301 / 304); PA |
| Materials (wetted parts) | stainless steel (1.4305 / 303); ceramics; FKM |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection G 1/4 external thread Internal thread:M5 |
| Restrictor element integrated | no (can be retrofitted) |
| Displays / operating elements |
|---|
| Display | | Power | LED, green | | Switching status | 2 x LED, yellow |
|
| Teach function | yes |
| Remarks |
|---|
| Pack quantity | 1 pcs. |
| Electrical connection |
|---|
| Connection | Connector: 1 x M12; Contacts: gold-plated |