| Product characteristics |
| Output signal |
switching signal; analogue signal; (configurable) |
| Measuring range [bar] |
0...10 |
| Process connection |
threaded connection Aseptoflex external thread Aseptoflex |
| Application |
| Special feature |
Gold-plated contacts |
| Application |
flush mountable for the food and beverage industry |
| Installation |
freely rotatable housing 350° |
| Media |
viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature [°C] |
-25...125; (145 max. 1h) |
| Min. bursting pressure [bar] |
150 |
| Pressure rating [bar] |
50 |
| Type of pressure |
relative pressure |
| No dead space |
yes |
| Electrical data |
| Operating voltage [V] |
20...30 DC |
| Current consumption [mA] |
< 60 |
| Min. insulation resistance [MΩ] |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
0.2 |
| Integrated watchdog |
yes |
| Inputs / outputs |
| Number of inputs and outputs |
Number of digital outputs: 1; Number of analogue outputs: 1 |
| Outputs |
| Total number of outputs |
2 |
| Output signal |
switching signal; analogue signal; (configurable) |
| Electrical design |
PNP |
| Number of digital outputs |
1 |
| Max. voltage drop switching output DC [V] |
2 |
| Permanent current rating of switching output DC [mA] |
250 |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4...20 |
| Max. load [Ω] |
500 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
| Measuring/setting range |
| Measuring range [bar] |
0...10 |
| Set point SP [bar] |
0.1...10 |
| Reset point rP [bar] |
0.05...9.95 |
| In steps of [bar] |
0.05 |
| Accuracy / deviations |
| Switch point accuracy [% of the final value] |
< ± 1,5 |
| Repeatability [% of the final value] |
< ± 0,25; (with temperature fluctuations < 10 K) |
| Characteristics deviation [% of the final value] |
< ± 1,0 |
| Temperature drift per 10 K |
< ± 0.3 |
| Response times |
| Switching frequency for a given set response time of one output |
| Response time (dAP) |
[ms] |
3 |
6 |
10 |
17 |
30 |
60 |
125 |
250 |
500 |
| Switching frequency |
[Hz] |
170 |
80 |
50 |
30 |
16 |
8 |
4 |
2 |
1 |
|
| Response time [ms] |
at rectangular pressure characteristic; switch point (SPx) = 70 %; reset point (rPx) = 30 % |
| Delay time programmable dS, dr [s] |
0, 0,2,...10, 11,...50 |
| Max. response time analogue output [ms] |
3 |
| Software / programming |
| Adjustment of the switch point |
programming button |
| Parameter setting options |
hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping |
| Operating conditions |
| Ambient temperature [°C] |
-25...80 |
| Storage temperature [°C] |
-40...100 |
| Protection |
IP 67 |
| Tests / approvals |
| EMC |
| EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated |
10 V/m |
| EN 61000-4-4 Burst |
2 kV |
| EN 61000-4-6 HF conducted |
10 V |
|
| Shock resistance |
| DIN IEC 68-2-27 |
50 g (11 ms) |
|
| Vibration resistance |
| DIN IEC 68-2-6 |
20 g (10...2000 Hz) |
|
| Mechanical data |
| Materials |
stainless steel (1.4404 / 316L); PBT; PC; PA; EPDM/X; FKM |
| Materials (wetted parts) |
stainless steel (1.4404 / 316L); ceramics; PTFE |
| Min. pressure cycles |
100 million |
| Process connection |
threaded connection Aseptoflex external thread Aseptoflex |
| Displays / operating elements |
| Display |
| switching status |
LED, red |
| function display |
7-segment LED display |
| measured values |
7-segment LED display |
|
| Remarks |
| Pack quantity |
1 pcs. |
| Electrical connection |
| Connection |
Connector: 1 x M12; Contacts: gold-plated |