| Product characteristics |
| Output signal |
switching signal; analog signal; (configurable) |
| Measuring range |
| -0.013...0.25 bar |
-13...250 mbar |
-5...100 inH2O |
-1.3...25 kPa |
|
| Process connection |
threaded connection Aseptoflex external thread Aseptoflex |
| Application |
| System |
gold-plated contacts |
| Application |
flush mountable for the food and beverage industry |
| Installation |
Freely rotatable housing 350° |
| Media |
viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature [°C] |
-25...80 |
| Min. bursting pressure |
| 30000 mbar |
12000 inH2O |
3000 kPa |
|
| Pressure rating |
| 6000 mbar |
2400 inH2O |
600 kPa |
|
| Type of pressure |
relative pressure |
| No dead space |
yes |
| Electrical data |
| Operating voltage [V] |
20...30 DC |
| Current consumption [mA] |
< 60 |
| Min. insulation resistance [MΩ] |
100; (500 V DC) |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
0.2 |
| Integrated watchdog |
yes |
| Inputs / outputs |
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analog outputs: 1 |
| Outputs |
| Total number of outputs |
2 |
| Output signal |
switching signal; analog signal; (configurable) |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
2 |
| Output function |
normally open / closed; (configurable) |
| Max. voltage drop switching output DC [V] |
2 |
| Permanent current rating of switching output DC [mA] |
250 |
| Switching frequency DC [Hz] |
< 170 |
| Number of analog outputs |
1 |
| Analog current output [mA] |
4...20; (scalable 1:4) |
| Max. load [Ω] |
(Ub - 10 V) / 20 mA |
| Analog voltage output [V] |
0...10; (scalable 1:4) |
| Min. load resistance [Ω] |
2000 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
yes (non-latching) |
| Overload protection |
yes |
| Measuring/setting range |
| Measuring range |
| -0.013...0.25 bar |
-13...250 mbar |
-5...100 inH2O |
-1.3...25 kPa |
|
| Set point SP |
| -11...250 mbar |
-4.4...100 inH2O |
-1.1...25 kPa |
|
| Reset point rP |
| -12...249 mbar |
-4.8...99.6 inH2O |
-1.2...24.9 kPa |
|
| Analog start point |
| -13...188 mbar |
-5...74.9 inH2O |
-1.3...18.8 kPa |
|
| Analog end point |
| 50...250 mbar |
20.1...100 inH2O |
5...25 kPa |
|
| In steps of |
|
| Factory setting |
|
SP1 = 63 mbar |
rP1 = 58 mbar |
|
ASP = 0 mbar |
AEP = 250 mbar |
|
| Accuracy / deviations |
| Repeatability [% of the span] |
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation [% of the span] |
< ± 0,6; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
| Linearity deviation [% of the span] |
< ± 0,5; (Turn down 1:1) |
| Hysteresis deviation [% of the span] |
< ± 0,1; (Turn down 1:1) |
| Long-term stability [% of the span] |
< ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point [% of the span / 10 K] |
< ± 0,1; (0...80 °C) |
| Temperature coefficient span [% of the span / 10 K] |
< ± 0,4; (0...80 °C) |
| Reaction times |
| Response time [ms] |
< 3 |
| Damping for the switching output dAP [s] |
0...4 |
| Damping for the analog output dAA in steps [s] |
0 - 0,1 - 0,5 - 2 |
| Max. response time analog output [ms] |
3 |
| Software / programming |
| Parameter setting options |
hysteresis / window; normally open / closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; Zero point; span |
| Operating conditions |
| Ambient temperature [°C] |
-25...80 |
| Storage temperature [°C] |
-40...100 |
| Protection |
IP 67 |
| Tests / approvals |
| EMC |
| EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated |
10 V/m |
| EN 61000-4-4 Burst |
2 kV |
| EN 61000-4-6 HF conducted |
10 V |
|
| Shock resistance |
| DIN IEC 68-2-27 |
50 g (11 ms) |
|
| Vibration resistance |
| DIN IEC 68-2-6 |
20 g (10...2000 Hz) |
|
| MTTF [years] |
182 |
| Mechanical data |
| Weight [g] |
317 |
| Material |
stainless steel (1.4404 / 316L); PBT; PC; PEI; EPDM/X; FKM |
| Materials (wetted parts) |
ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE |
| Min. pressure cycles |
100 million |
| Process connection |
threaded connection Aseptoflex external thread Aseptoflex |
| Displays / operating elements |
| Display |
| Switching status |
2 x LED, red |
| Function display |
7-segment LED display |
| Measured values |
7-segment LED display |
|
| Display unit |
mbar; inH2O; kPa |
| Remarks |
| Remarks |
| The 3-A qualification is only valid if adapters with 3-A qualification are used for installation. |
|
| Pack quantity |
1 pcs. |
| Electrical connection |
| Connection |
Connector: 1 x M12; Contacts: gold-plated |